Florida Forestry Information
Special Management Zones
 Site Management Recommendations
 
Below is a Site Sensitivity Class (SSC) index showing the SSC associated with soil erodibility conditions and percent slope.  Click on the site sensitivity classifications in the table to view the site management recommendations associated with them.  Links to further information about soil erodibility and slope estimation are also provided on the index.  This information is from the Florida Department of Agriculture and Consumer Services Division of Forestry's Silviculture Best Management Practices, 2000 edition. 
 
Site Sensitivity Classification (SSC) Index
 
Soil Erodibility
K-Factor*
Slope= 0-2%
Slope= 3-7%
Slope= 8-12%
Slope= 13-17%
Slope= 18-22%
Slope= 22% +
Low
<0.20
A1
A2
A3
A4
A5
A6
Moderate
0.21-0.27
B1
B2
B3
B4
B5
B6
High
>0.28
C1
C2
C3
C4
C5
C6
 
* K-Factor: an index representing the potential erodibility of a soil by water based on soil texture. 
 
Soil Erodibility Guide
Slope Estimation Guide
SMZ Menu
BMP Menu
Home
 
 
Site Management Recommendations
SSC A1
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
35
35
Perennial (0-20 ft.)
35
None
35
Perennial (21-40 ft.)
75
None
75
Perennial (40+ft.)
200
None
200
OFW, ONRW, Class I Waters
200
None
200
LAKES
Intermittent
Stringer
35
35
Perennial
35
None
35
OFW, ONRW, Class I Waters
200
None
200
SINKHOLES
Intermittent
Stringer
35
35
Perennial
35
None
35
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
None
200
none
Temp. Roads/Skid Trails
0-300
Water Bars
250
Firelines
0-300
Water Bars
250
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC A2
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
45
45
Perennial (0-20 ft.)
35
10
45
Perennial (21-40 ft.)
75
None
75
Perennial (40+ft.)
200
None
200
OFW, ONRW, Class I Waters
200
None
200
LAKES
Intermittent
Stringer
45
45
Perennial
35
10
45
OFW, ONRW, Class I Waters
200
None
200
SINKHOLES
Intermittent
Stringer
45
45
Perennial
35
10
45
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
200
120
180
Temp. Roads/Skid Trails
0-300
Water Bars
135
Firelines
0-300
Water Bars
135
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC A3
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
60
60
Perennial (0-20 ft.)
35
25
60
Perennial (21-40 ft.)
75
None
75
Perennial (40+ft.)
200
None
200
OFW, ONRW, Class I Waters
200
None
200
LAKES
Intermittent
Stringer
60
60
Perennial
35
25
60
OFW, ONRW, Class I Waters
200
None
200
SINKHOLES
Intermittent
Stringer
60
60
Perennial
35
25
35
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
150
100
140
Temp. Roads/Skid Trails
0-300
Water Bars
80
Firelines
0-300
Water Bars
80
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC A4
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
300
300
Perennial (0-20 ft.)
35
265
300
Perennial (21-40 ft.)
75
225
300
Perennial (40+ft.)
200
100
300
OFW, ONRW, Class I Waters
200
100
300
LAKES
Intermittent
Stringer
300
300
Perennial
35
265
300
OFW, ONRW, Class I Waters
200
100
300
SINKHOLES
Intermittent
Stringer
300
300
Perennial
35
265
300
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
125
75
125
Temp. Roads/Skid Trails
0-300
Water Bars
60
Firelines
0-300
Water Bars
60
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC A5
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
300
300
Perennial (0-20 ft.)
35
265
300
Perennial (21-40 ft.)
75
225
300
Perennial (40+ft.)
200
100
300
OFW, ONRW, Class I Waters
200
100
300
LAKES
Intermittent
Stringer
300
300
Perennial
35
265
300
OFW, ONRW, Class I Waters
200
100
300
SINKHOLES
Intermittent
Stringer
300
300
Perennial
35
265
300
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
100
50
120
Temp. Roads/Skid Trails
0-300
Water Bars
45
Firelines
0-300
Water Bars
45
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC A6
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
300
300
Perennial (0-20 ft.)
35
265
300
Perennial (21-40 ft.)
75
225
300
Perennial (40+ft.)
200
100
300
OFW, ONRW, Class I Waters
200
100
300
LAKES
Intermittent
Stringer
300
300
Perennial
35
265
300
OFW, ONRW, Class I Waters
200
100
300
SINKHOLES
Intermittent
Stringer
300
300
Perennial
35
265
300
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
75
40
110
Temp. Roads/Skid Trails
0-300
Water Bars
30
Firelines
0-300
Water Bars
30
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC B1
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
35
35
Perennial (0-20 ft.)
35
None
35
Perennial (21-40 ft.)
75
None
75
Perennial (40+ft.)
200
None
200
OFW, ONRW, Class I Waters
200
None
200
LAKES
Intermittent
Stringer
35
35
Perennial
35
None
35
OFW, ONRW, Class I Waters
200
None
200
SINKHOLES
Intermittent
Stringer
35
35
Perennial
35
None
35
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
None
150
None
Temp. Roads/Skid Trails
0-300
Water Bars
250
Firelines
0-300
Water Bars
250
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC B2
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
60
60
Perennial (0-20 ft.)
35
25
60
Perennial (21-40 ft.)
75
None
75
Perennial (40+ft.)
200
None
200
OFW, ONRW, Class I Waters
200
None
200
LAKES
Intermittent
Stringer
60
60
Perennial
35
25
60
OFW, ONRW, Class I Waters
200
None
200
SINKHOLES
Intermittent
Stringer
60
60
Perennial
35
25
60
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
200
120
180
Temp. Roads/Skid Trails
0-300
Water Bars
135
Firelines
0-300
Water Bars
135
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
  
Site Management Recommendations
SSC B3
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
75
75
Perennial (0-20 ft.)
35
40
75
Perennial (21-40 ft.)
75
None
75
Perennial (40+ft.)
200
None
200
OFW, ONRW, Class I Waters
200
None
200
LAKES
Intermittent
Stringer
75
75
Perennial
35
40
75
OFW, ONRW, Class I Waters
200
None
200
SINKHOLES
Intermittent
Stringer
75
75
Perennial
35
40
75
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
150
100
140
Temp. Roads/Skid Trails
0-300
Water Bars
80
Firelines
0-300
Water Bars
80
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC B4
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
300
300
Perennial (0-20 ft.)
35
265
300
Perennial (21-40 ft.)
75
225
300
Perennial (40+ft.)
200
100
300
OFW, ONRW, Class I Waters
200
100
300
LAKES
Intermittent
Stringer
300
300
Perennial
35
265
300
OFW, ONRW, Class I Waters
200
100
300
SINKHOLES
Intermittent
Stringer
300
300
Perennial
35
265
300
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
125
75
125
Temp. Roads/Skid Trails
0-300
Water Bars
60
Firelines
0-300
Water Bars
60
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC B5
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
300
300
Perennial (0-20 ft.)
35
265
300
Perennial (21-40 ft.)
75
225
300
Perennial (40+ft.)
200
100
300
OFW, ONRW, Class I Waters
200
100
300
LAKES
Intermittent
Stringer
300
300
Perennial
35
265
300
OFW, ONRW, Class I Waters
200
100
300
SINKHOLES
Intermittent
Stringer
300
300
Perennial
35
265
300
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
100
50
120
Temp. Roads/Skid Trails
0-300
Water Bars
45
Firelines
0-300
Water Bars
45
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC B6
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
300
300
Perennial (0-20 ft.)
35
265
300
Perennial (21-40 ft.)
75
225
300
Perennial (40+ft.)
200
100
300
OFW, ONRW, Class I Waters
200
100
300
LAKES
Intermittent
Stringer
300
300
Perennial
35
265
300
OFW, ONRW, Class I Waters
200
100
300
SINKHOLES
Intermittent
Stringer
300
300
Perennial
35
265
300
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
75
40
110
Temp. Roads/Skid Trails
0-300
Water Bars
30
Firelines
0-300
Water Bars
30
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC C1
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
35
35
Perennial (0-20 ft.)
35
None
35
Perennial (21-40 ft.)
75
None
75
Perennial (40+ft.)
200
None
200
OFW, ONRW, Class I Waters
200
None
200
LAKES
Intermittent
Stringer
35
35
Perennial
35
None
35
OFW, ONRW, Class I Waters
200
None
200
SINKHOLES
Intermittent
Stringer
35
35
Perennial
35
None
35
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
None
150
None
Temp. Roads/Skid Trails
0-300
Water Bars
250
Firelines
0-300
Water Bars
250
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
  
Site Management Recommendations
SSC C2
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
60
60
Perennial (0-20 ft.)
35
25
60
Perennial (21-40 ft.)
75
None
75
Perennial (40+ft.)
200
None
200
OFW, ONRW, Class I Waters
200
None
200
LAKES
Intermittent
Stringer
60
60
Perennial
35
25
60
OFW, ONRW, Class I Waters
200
None
200
SINKHOLES
Intermittent
Stringer
60
60
Perennial
35
25
60
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
200
120
180
Temp. Roads/Skid Trails
0-300
Water Bars
135
Firelines
0-300
Water Bars
135
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC C3
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
80
80
Perennial (0-20 ft.)
35
45
80
Perennial (21-40 ft.)
75
5
80
Perennial (40+ft.)
200
None
200
OFW, ONRW, Class I Waters
200
None
200
LAKES
Intermittent
Stringer
80
80
Perennial
35
45
80
OFW, ONRW, Class I Waters
200
None
200
SINKHOLES
Intermittent
Stringer
80
80
Perennial
35
45
80
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
150
100
140
Temp. Roads/Skid Trails
0-300
Water Bars
80
Firelines
0-300
Water Bars
80
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC C4
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
300
300
Perennial (0-20 ft.)
35
265
300
Perennial (21-40 ft.)
75
225
300
Perennial (40+ft.)
200
100
300
OFW, ONRW, Class I Waters
200
100
300
LAKES
Intermittent
Stringer
300
300
Perennial
35
265
300
OFW, ONRW, Class I Waters
200
100
300
SINKHOLES
Intermittent
Stringer
300
300
Perennial
35
265
300
 
 ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
125
75
125
Temp. Roads/Skid Trails
0-300
Water Bars
60
Firelines
0-300
Water Bars
60
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
 
Site Management Recommendations
SSC C5
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
300
300
Perennial (0-20 ft.)
35
265
300
Perennial (21-40 ft.)
75
225
300
Perennial (40+ft.)
200
100
300
OFW, ONRW, Class I Waters
200
100
300
LAKES
Intermittent
Stringer
300
300
Perennial
35
265
300
OFW, ONRW, Class I Waters
200
100
300
SINKHOLES
Intermittent
Stringer
300
300
Perennial
35
265
300
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
100
50
120
Temp. Roads/Skid Trails
0-300
Water Bars
45
Firelines
0-300
Water Bars
45
 
SSC Index
Special Management Zones Menu
BMP Menu
Home
     
Site Management Recommendations
SSC C6
 
SPECIAL MANAGEMENT ZONES (each side of water body)
Stream Class
Primary Zone (ft.)
Secondary Zone (ft.)
Total SMZ (ft.)
STREAMS
Intermittent (all)
Stringer
300
300
Perennial (0-20 ft.)
35
265
300
Perennial (21-40 ft.)
75
225
300
Perennial (40+ft.)
200
100
300
OFW, ONRW, Class I Waters
200
100
300
LAKES
Intermittent
Stringer
300
300
Perennial
35
265
300
OFW, ONRW, Class I Waters
200
100
300
SINKHOLES
Intermittent
Stringer
300
300
Perennial
35
265
300
 
ROAD CONSTRUCTION And DRAINAGE RECOMMENDATIONS
Structure
Zone Width (ft.)
Treatments Allowed
Spacing (ft.)
Permanent Roads
0-300
Culvert or Cross Ditch
Water Turnouts
Broad-base Dips
75
40
110
Temp. Roads/Skid Trails
0-300
Water Bars
30
Firelines
0-300
Water Bars
30
 
SSC Index
Special Management Zones Menu
BMP Menu
Home